Title: Viral load assay performs comparably to early infant diagnosis assay to diagnose infants with HIV in Mozambique: a prospective observational study
Authors: Vubil, Adolfo
Nhachigule, Carina
Loquiha, Osvaldo
Meggi, Bindiya
Mabunda, Nedio
Bollinger, Timothy
Sacks, Jilian A.
Jani, Ilesh
Vojnov, Lara
Keywords: Viral load monitoring
Virology
Paediatrics
LMIC
Africa
Diagnostics
Monitoramento de carga viral
Virologia
Pediatria
Issue Date: 8-Jan-2020
Publisher: Wiley Online Library
Abstract: Introduction Viral load testing is essential to manage HIV disease, especially in infants and children. Early infant diagnosis (EID) is performed using nucleic-acid testing in children under 18 months. Resource-limited health systems face severe challenges to scale-up both viral load and EID to unprecedented levels. Streamlining laboratory systems would be beneficial to improve access to quality testing and to increase efficiency of antiretroviral treatment programmes. We evaluated the performance of viral load testing to serve as an EID assay in children younger than 18 months. Methods This study was an observational, prospective study, including children between one and 18 months of age who were born to HIV-positive mothers in 134 health facilities in Maputo City and Maputo Province, Mozambique. Dried blood spot specimens from heel or toe pricks were collected between January and April 2018, processed using SPEX buffer for both assays, and tested for routine EID and viral load testing using the Roche CAP/CTM HIV-1 Qualitative v2 and Roche CAP/CTM HIV-1 Quantitative v2 assays respectively. The sensitivity, specificity and positive and negative predictive values were estimated using the EID results as the reference standard. Results A total of 1021 infants were included in the study, of which 47% were female. Over 95% of mothers and children were on antiretroviral treatment or received antiretroviral prophylaxis respectively. The sensitivity and specificity of using the viral load assay to detect infection were 100% (95% CI: 96.2 to 100%) and 99.9% (95% CI: 99.4 to 100%). The positive and negative predictive values were 99.0% (95% CI: 94.3 to 100%) and 100% (95% CI: 99.6 to 100%). The McNemar’s test was 1.000 and Cohen’s kappa was 0.994. Conclusions The comparable performance suggests that viral load assays can be used as an infant diagnostic assay. Infants with either low levels of viraemia or high cycle threshold values should be repeat tested to ensure the result is truly positive prior to treatment initiation, regardless of assay used. Viral load assays could replace traditional EID testing, substantially streamlining molecular laboratory services for children and lowering costs, with the additional advantage of providing baseline viral load results for antiretroviral treatment management
URI: http://www.repositorio.uem.mz/handle258/900
Appears in Collections:Artigos Publicados em Revistas Cientificas - FC

Files in This Item:
File Description SizeFormat 
2020 - Vubil, Adolfo. pdf315.59 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.